HOME > Metal fatigue identification device > Metal fatigue identification device specifications

Metal fatigue identification device specifications

  MFD101B MFD102B
  MFD101B MFD102B
Shape 320mm W×155mm H×320㎜D 150mm W×190mm H×68mm D
Weight 5.0kg 0.9kg
Power supply AC100V±10% 50/60Hz

AC100V±10% 50/60Hz

or Nickel hydrogen storage battery size AA (1.2V) 6 pieces (charger attached)
Usage of frequency band 50Hz-39.99kHz、10Hz STEP 50Hz-39.99kHz、10Hz STEP
Sensor drive output (sine wave) Maximum voltage 10Vpeak
Maximum electric current 0.5Apeak
Maximum voltage 0.2Vpeak
Maximum electric current 10mApeak
Sensor measuring signal input Ground wire maximum voltage1Vp-p Ground wire maximum voltage1Vp-p
Level adjustment range 0-±10Vpeak

0-±0.2Vpeak

(Single turn half fixed trimmer)

 

Product appearance and specifications may change without notice due to improvements.

 

This device is a product developed through the guidance and support of the Japan Small and Medium Enterprise Corporation, Kanagawa Industrial Technology Research Institute, and Yokohama National University.

Contact E-mail >>